Material ID | Name | Material | Weight | Specified cantilever load (SCL) | Maximum design cantilever load (MDCL) | Specified tensile load (STL) | Specified mechanical load (SML) | Maximum design tensile load (MDTL) | ||
---|---|---|---|---|---|---|---|---|---|---|
3EGF019711 | Insulator 3 kV Tongue/Tubecap D42-70 3 sheds | Composite | 4,92 kg | 8 kN | 4 kN | 50 kN | Request | |||
3EGF018723 | Insulator 3 kV Tongue/Tongue 3 sheds | Composite | 2,72 kg | 140 kN | 56 kN | Request | ||||
3EGF021023 | Insulator 3kV M16 / 2sheds KW240 plastic OCR | Composite | 0,99 kg | 6 kN | 2,4 kN | 10 kN | Request |
Material ID | Name | Nominal voltage | Creepage Path | Rated impulse withstand voltage | Power-frequency withstand voltage, wet | Arcing distance | ||
---|---|---|---|---|---|---|---|---|
3EGF019711 | Insulator 3 kV Tongue/Tubecap D42-70 3 sheds | 3 kV | 345 mm | 95 kV | 40 kV | 170 mm | Request | |
3EGF018723 | Insulator 3 kV Tongue/Tongue 3 sheds | 3 kV | 360 mm | 120 kV | 45 kV | 173 mm | Request | |
3EGF021023 | Insulator 3kV M16 / 2sheds KW240 plastic OCR | 3 kV | 240 mm | 60 kV | 20 kV | 178 mm | Request |